HAWSEDC PROFILE DRAFTER QUICK REFERENCE

CATCH BASINS PLOT ON A PIPE PROFILE POINT BY INCLUDING THE TEXT "CB", "INLET", OR "BASIN" IN THE LABEL AND THE GRATE OR TC ELEVATION PRECEDED BY "GRATE=" OR "TC=". PRO ASSUMES 8" DIFFERENCE BETWEEN TC AND GRATE.
CATCH BASINS, BROKEN AVAILABLE THROUGH DATA FILES ONLY. SAME AS NORMAL CATCH BASINS, BUT PUT A LOWER PLOTTING ELEVATION IN THE NUM2 FIELD.
CIRCLES ONLY FOR DRAFTING REFERENCE USE PROHT 1000.
CURB ELEVATION PREFIX CHANGE THE PREFIX OF THE LOWER CURB ELEVATION LABEL BY PUTTING AN ALTERNATE LABEL IN THE PROTYP FIELD (SUCH AS "P", "BC", OR "NG" TO REPLACE "G").
CURB HEIGHT ENTER THE CURB HEIGHT IN INCHES IN THE PROHT FIELD.
DECIMAL PLACES SEE PRECISION.
ELEVATIONS ENTER ELEVATIONS IN FIELD 4 OF THE PRFPNT LINE OR IN THE LABEL FIELD.
EXISTING GRAPHICS MAKE ANY PROFILE EXISTING BY STARTING THE PROTYP FIELD WITH AN "X".
EXISTING GROUND, UNLABELED USE A LINE ONLY PROFILE.
FILE FORMAT CHANGE THE FILE FORMAT OR TAB WIDTH BY USING SOMETHING OTHER THAN 10 ON THE COLWID LINE. CONVERT OLD FILES BY USING THE PROFC COMMAND.
GRADE BREAK AND CHANGE DIAMONDS PLOT A DIAMOND BY INCLUDING "GC", "GB", "G.C.", "G.B.", "GRADE CHANGE", OR "GRADE BREAK" IN THE LABEL FIELD.
INCREASING PIPE SIZE AT A MANHOLE REPEAT THE PRFPNT LINE TWICE WITH NEWPRF AND PROTYP LINES BETWEEN THE TWO. SUPPRESS THE PIPE STATION AND ELEVATION AND DON'T INCLUDE A LABEL ON THE FIRST PRFPNT LINE.
LABEL FIELD FIELD 7 OF THE PRFPNT LINE.
LABEL WRAPPING WRAP LABEL TEXT ONTO MULTIPLE LINES BY PUTTING A SEMI-COLON (;) WHERE YOU WANT LINE BREAKS.
LATERAL PROFILES SEE STREET CROSS SECTION PROFILES.
LINE ONLY PROFILE (UNANNOTATED) USE PROHT -10000 WITH PROFILE POINTS THAT HAVE ONLY STATION AND ELEVATION.
MANHOLES PLOT A MANHOLE ON A PIPE PROFILE POINT BY INCLUDING THE TEXT "RIM=" FOLLOWED BY THE RIM ELEVATION IN THE LABEL FIELD.
MANHOLES WITH INVERTS LOWER THAN PIPE SUPPRESS THE PIPE STATION AND ELEVATION AT THE MANHOLE AND DON'T PLOT THE MANHOLE WITH THE PIPES. PLOT IT WITH ANOTHER PRFPNT LINE SEPARATED BY A NEWPRF LINE WITH THE APPROPRIATE PIPE SIZE, WALL THICKNESS, AND ELEVATIONS.
MANHOLES, BROKEN AVAILABLE THROUGH DATA FILES ONLY. SAME AS NORMAL MANHOLES, BUT PUT THE TRUE RIM PLOTTING ELEVATION IN THE NUM2 FIELD.
NUM2 FIELD 6 OF THE PRFPNT LINE. GIVES PLOTTING ELEVATION FOR BREAKING MANHOLES AND CATCH BASINS. GIVES UNLABELED SIZE FOR UTILITY CROSSING PIPES.
OFFSET LABEL IF YOU WANT OFFSET LABELED, ENTER IT AS A REAL NUMBER IN FIELD 3 OF THE PRFPNT LINE.
PIPE CROSSINGS SEE UTILITY CROSSINGS.
PIPE ELEVATION LABEL THE WORDING OF THE PIPE ELEVATION LABEL IS HARD CODED INTO PRO.
PIPE ELEVATION LEADER DIRECTION FORCE THE LEADER INTO ANY OF FOUR DIRECTIONS BY PUTTING THE QUADRANT NUMBER IN THE THOUSANDTHS PLACE (100.003) OF THE ELEVATION FIELD. THE DEFAULT IS QUADRANT 4 EXCEPT AT THE END MATCH SHEET POINT ("SHEET" IN THE LABEL), WHERE IT IS QUADRANT 3. IN COORDINATE SYSTEMS AND TRIGONOMETRY, QUADRANT 1 IS UPPER RIGHT (0 TO 90 DEGREES), 2 IS UPPER LEFT, 3 IS LOWER LEFT, AND 4 IS LOWER RIGHT.
PIPE PROFILE USE PROHT BETWEEN -10000 AND 0.
PIPE WALL THICKNESS SEE WALL THICKNESS.
PRECISION USE THE PRECIS LINE TO SET THE NUMERIC PRECISION FOR STATION, OFFSET, ELEVATION, AND SLOPE.
PROHT THE PROHT FIELD IS FIELD 2 OF THE PROTYP LINE.
PROPOSED GRAPHICS PROPOSED GRAPHICS ARE DRAWN UNLESS THERE IS AN "X" AT THE BEGINNING OF THE PROTYP FIELD.
PROPOSED GROUND, UNLABELED USE A LINE ONLY PROFILE.
PROTYP FIELD 4 OF THE PROTYP LINE. GIVES PIPE TYPE (WAT, SEW, SD, IRR, GAS) OR ALTERNATE CURB ELEVATION PREFIX AND CALLS FOR EXISTING PROFILE GRAPHICS IF "X" IS THE FIRST LETTER IN THE FIELD.
SLOPE LABELS THE WORDING AND POSITIONING OF SLOPE LABELS IS HARD CODED INTO PRO.
STATION ENTER THE STATION AS A REAL NUMBER IN FIELD 2 OF THE PRFPNT LINE.
STORM DRAIN LATERALS SEE STREET CROSS SECTION PROFILES
STREET CROSS SECTION PROFILES FOR PLOTTING PURPOSES, ROAD STATION IS MEANINGLESS, AND CENTERLINE OFFSET IS USED AS PLOTTING STATION. PUT THE OFFSET IN BOTH THE STATION AND OFFSET FIELDS. SUPPRESS THE STATION. PUT TEXT WITH THE ROAD STATION SIMILAR TO THIS EXAMPLE IN THE LABEL "MH, RIM=45.6;STA 123+89.45".
SUPPRESSING THE ELEVATION LABEL ENTER THE ELEVATION AS A NEGATIVE TO SUPPRESS THE ELEVATION LABEL.
SUPPRESSING THE ENTIRE ENDPOINT LABEL SUPPRESS BOTH THE STATION AND THE ELEVATION. USE PROHT -10000 FOR FULLY NON-LABELED PROFILES.
SUPPRESSING THE OFFSET LABEL LEAVE THE OFFSET FIELD BLANK TO SUPPRESS THE OFFSET LABEL.
SUPPRESSING THE SLOPE LABEL ENTER 1000 IN THE SLOPE FIELD TO SUPPRESS THE SLOPE. SUPPRESSION IS NOT NEEDED FOR PROHT -10000, -20000, OR 1000.
SUPPRESSING THE STATION LABEL PLACE A 1 IN THE THOUSANDTHS PLACE (1000.001) TO SUPPRESS THE STATION LABEL.
TAB SPACING SEE FILE FORMAT.
TRUE LENGTH DIMENSIONS USE PROHT -20000 AND USE TWO PRFPNT LINES TO GIVE THE ENDPOINT STATIONS AND ELEVATIONS FOR THE DIMENSION. ENTER THE DIMENSION TEXT IN THE LABEL FIELD OF THE SECOND POINT.
UTILITY CLEARANCES USE PROHT -20000 AND USE TWO PRFPNT LINES TO GIVE THE ENDPOINT STATIONS AND ELEVATIONS FOR THE DIMENSION. ENTER THE DIMENSION TEXT IN THE LABEL FIELD OF THE SECOND POINT. MAKE SURE DIMTIH IS 1.
UTILITY CROSSING USE PROHT 1000. FOR EACH PRFNPT LINE, ADD SIZE AND WALL THICKNESS INFORMATION.
UTILITY CROSSING CLEARANCE DIMENSION USE PROHT -20000 AND USE TWO PRFPNT LINES TO GIVE THE ENDPOINT STATIONS AND ELEVATIONS FOR THE DIMENSION. ENTER THE DIMENSION TEXT IN THE LABEL FIELD OF THE SECOND POINT. MAKE SURE DIMTIH IS 1.
UTILITY CROSSING LEADER DIRECTION SEE PIPE ELEVATION LEADER DIRECTION
UTILITY CROSSING PIPE ELEVATION LABEL THE PIPE "TOP*=", "BOT*=", OR "INV*=" ELEVATION IN THE LABEL FIELD. PRO WILL IGNORE THE ELEVATION IN THE ELEVATION FIELD.
UTILITY CROSSING PIPE ELEVATION WHEN UNKNOWN SEE UTILITY CROSSING PIPE UNLABELED ELEVATION.
UTILITY CROSSING PIPE SIZE INCLUDE THE PIPE SIZE FOLLOWED BY THE TEXT "IN*" OR """ IN THE LABEL FIELD.
UTILITY CROSSING PIPE SIZE WHEN UNKNOWN SEE UTILITY CROSSING PIPE UNLABELED SIZE
UTILITY CROSSING PIPE UNLABELED ELEVATION INCLUDE THE PIPE INVERT ELEVATION IN THE ELEVATION FIELD.
UTILITY CROSSING PIPE UNLABELED SIZE PUT THE ESTIMATED SIZE FOR PLOTTING IN THE NUM2 FIELD.
UTILITY CROSSING PIPE WALL THICKNESS PUT THE POSITIVE WALL THICKNESS IN INCHES IN THE SLOPE FIELD.
VALLEY GUTTERS USE PROHT 0 AND SUPPRESS THE LABELS AT THE ENDPOINTS.
WALL THICKNESS FOR RUNNING PIPE PROFILES, PUT NEGATIVE WALL THICKNESS IN INCHES IN FIELD 3 OF THE PROTYP LINE. FOR PIPE CROSSINGS, PUT THE POSITIVE WALL THICKNESS IN INCHES IN THE SLOPE FIELD OF THE PRFPNT LINE.
WRAPPING THE LABEL SEE LABEL WRAPPING